I was at the dental office the other day, and they did a panoramic x ray and three dental cone beam computed tomography (CT) scans, as the first two got the wrong area. Should I be worried about too much radiation at one time?

A

If you look at the answer to Question 11138, it gives cone beam CT doses for various machines. The average effective dose for cone beam CT scans is given as 130 microsieverts (µSv), which is 0.13 millisievert (mSv). The average effective dose for panoramic procedures is about a tenth of this. Since they did the cone beam CT three times, your effective dose would be around 0.4 mSv from the cone beam CT, and your dose from the panoramic x-ray procedure is 0.014 mSv, barely more than the rounding error. So your total dose is about (3 × 0.13) + 0.014 = 0.44 mSv.

These are very small doses. Below 100 mSv above background, the observed radiation effects in people are not statistically different from zero. In other words, the risks of health effects from these and other diagnostic imaging procedures are either too small to be observed or are nonexistent. And, of course, you benefited from the procedure. The benefits from properly performed, clinically indicated, diagnostic imaging procedures far outweigh any hypothetical cancer risk.

Kent Lambert, CHP

Answer posted on 4 October 2016. The information posted on this web page is intended as general reference information only. Specific facts and circumstances may affect the applicability of concepts, materials, and information described herein. The information provided is not a substitute for professional advice and should not be relied upon in the absence of such professional advice. To the best of our knowledge, answers are correct at the time they are posted. Be advised that over time, requirements could change, new data could be made available, and Internet links could change, affecting the correctness of the answers. Answers are the professional opinions of the expert responding to each question; they do not necessarily represent the position of the Health Physics Society.